Help


[permalink] [id link]
+
Page "Confocal laser scanning microscopy" ¶ 9
from Wikipedia
Edit
Promote Demote Fragment Fix

Some Related Sentences

fluorescence and observations
He decided to do quantitative research following the discovery that the visual observations of color did not match the dominant colors obtained photographically when using models of fluorescence.

fluorescence and resolution
* 1978: Theoretical basis of super resolution 4Pi microscopy & design of a confocal laser scanning fluorescence microscope
SPDM ( spectral precision distance microscopy ), the basic localization microscopy technology is a light optical process of fluorescence microscopy which allows position, distance and angle measurements on " optically isolated " particles ( e. g. molecules ) well below the theoretical limit of resolution for light microscopy.
For example, from a data set comprising fluorescence spectra from a series of samples each containing multiple fluorophores, multivariate curve resolution methods can be used to extract the fluorescence spectra of the individual fluorophores, along with their relative concentrations in each of the samples, essentially unmixing the total fluorescence spectrum into the contributions from the individual components.
* C1XS or X-ray fluorescence spectrometer covering 1-10 keV, mapped the abundance of Mg, Al, Si, Ca, Ti, and Fe at the surface with a ground resolution of 25 km, and monitored solar flux.
The " fluorescence microscope " refers to any microscope that uses fluorescence to generate an image, whether it is a more simple set up like an epifluorescence microscope, or a more complicated design such as a confocal microscope, which uses optical sectioning to get better resolution of the fluorescent image.
As only light produced by fluorescence very close to the focal plane can be detected, the image's optical resolution, particularly in the sample depth direction, is much better than that of wide-field microscopes.
However, as much of the light from sample fluorescence is blocked at the pinhole, this increased resolution is at the cost of decreased signal intensity – so long exposures are often required.
The unique combination of high spatial and temporal resolution, nondestructive compatibility with living cells and organisms, and molecular specificity insure that fluorescence techniques will remain central in the analysis of protein networks and systems biology.

fluorescence and limit
Cuvettes to be used in fluorescence spectroscopy must be clear on all four sides because fluorescence is measured at a right-angle to the beam path to limit contributions from beam itself.
The equation describing the fluorescence as a function of time is particularly simple in another limit.

fluorescence and confocal
The rise of fluorescence microscopy drove the development of a major modern microscope design, the confocal microscope.
This, together with their small size, facilitates live cell imaging using both fluorescence and confocal laser scanning microscopy.
During the next decade, confocal fluorescence microscopy was developed into a fully mature technology, in particular by groups working at the University of Amsterdam and the European Molecular Biology Laboratory ( EMBL ) in Heidelberg and their industry partners.
A beam splitter separates off some portion of the light into the detection apparatus, which in fluorescence confocal microscopy will also have a filter that selectively passes the fluorescent wavelengths while blocking the original excitation wavelength.
* Two-photon excitation microscopy: Although they use a related technology ( both are laser scanning microscopes ), multiphoton fluorescence microscopes are not strictly confocal microscopes.
In microscopy, the development and refinement of the confocal microscope, the fluorescence microscope, and the total internal reflection fluorescence microscope all belong to the field of biophotonics.
Fluorescent molecules can be visualised using fluorescence microscopy or confocal microscopy.
These microscopes may also be fitted with accessories for fitting still and video cameras, fluorescence illumination, confocal scanning and many other applications.
In fluorescence microscopy, fluorescence confocal laser scanning microscopy, as well as in molecular biology, FRET is a useful tool to quantify molecular dynamics in biophysics and biochemistry, such as protein-protein interactions, protein – DNA interactions, and protein conformational changes.
These microscopes have become an important part in the field of biology, opening the doors for more advanced microscope designs, such as the confocal microscope and the total internal reflection fluorescence microscope ( TIRF ).
Lasers are most widely used for more complex fluorescence microscopy techniques like confocal microscopy and total internal reflection fluorescence microscopy while xenon and mercury lamps with an excitation filter or LEDs are commonly used for widefield epifluorescence microscopes.
In 1978 first theoretical ideas have been developed to break this barrier by using a 4Pi microscope as a confocal laser scanning fluorescence microscope where the light is focused ideally from all sides to a common focus which is used to scan the object by ' point-by-point ' excitation combined with ' point-by-point ' detection.
The principle of confocal imaging was patented in 1957 by Marvin Minsky and aims to overcome some limitations of traditional wide-field fluorescence microscopes.
Multiphoton fluorescence microscopy has similarities to confocal laser scanning microscopy.
In addition, there has been a flurry of activity extending FCS in various ways, for instance to laser scanning and spinning-disk confocal microscopy ( from a stationary, single point measurement ), in using cross-correlation ( FCCS ) between two fluorescent channels instead of autocorrelation, and in using Förster Resonance Energy Transfer ( FRET ) instead of fluorescence.

fluorescence and microscopy
Recent improvements in fluorescence microscopy techniques have provided novel and amazing insight into the dynamic structure of a single cell organism.
In the case of the former, detection of the location of the " immuno-stained " protein occurs via fluorescence microscopy.
The fluorescence lifetime is an important parameter for practical applications of fluorescence such as fluorescence resonance energy transfer and Fluorescence-lifetime imaging microscopy.
* When scanning the fluorescent intensity across a plane one has fluorescence microscopy of tissues, cells, or subcellular structures, which is accomplished by labeling an antibody with a fluorophore and allowing the antibody to find its target antigen within the sample.
Recovery of the protein crystals requires imaging which can be done by the intrinsic fluorescence of the protein or by using transmission microscopy.
This high specificity led to the widespread use of fluorescence light microscopy in biomedical research.
For instance, laser microscopy focused on biological applications uses ultrashort pulse lasers, or femtosecond lasers, in a number of techniques labeled as nonlinear microscopy, saturation microscopy, and multiphoton fluorescence microscopy.
The most recent developments in light microscope largely centre on the rise of fluorescence microscopy in biology.
In fluorescence microscopy, many wavelengths of light, ranging from the ultraviolet to the visible can be used to cause samples to fluoresce to allow viewing by eye or with the use of specifically sensitive cameras.
Physical coupling between these two organelles had previously been observed in electron micrographs and has more recently been probed with fluorescence microscopy.
Monoclonal antibodies, specific to the virus, are also used for detection, as in fluorescence microscopy.
The out-of-focus light is suppressed: most of the returning light is blocked by the pinhole, which results in sharper images than those from conventional fluorescence microscopy techniques and permits one to obtain images of planes at various depths within the sample ( sets of such images are also known as z stacks ).

fluorescence and is
In fluorescence spectroscopy, the fluorescence anisotropy, calculated from the polarization properties of fluorescence from samples excited with plane-polarized light, is used, e. g., to determine the shape of a macromolecule.
The fluorescence signal is captured by a photomultiplier a known distance downstream of the de Laval nozzle.
This process is called fluorescence.
When the emission of the photon is immediate, this phenomenon is called fluorescence, a type of photoluminescence.
The most striking examples of fluorescence occur when the absorbed radiation is in the ultraviolet region of the spectrum, and thus invisible to the human eye, and the emitted light is in the visible region.
The chemical compound responsible for this fluorescence is matlaline, which is the oxidation product of one of the flavonoids found in this wood.
Molecular oxygen ( O < sub > 2 </ sub >) is an extremely efficient quencher of fluorescence just because of its unusual triplet ground state.
The maximum fluorescence quantum yield is 1. 0 ( 100 %); every photon absorbed results in a photon emitted.
Another way to define the quantum yield of fluorescence, is by the rate of excited state decay:
The quinine salt quinine sulfate in a sulfuric acid solution is a common fluorescence standard.
where is the concentration of excited state molecules at time, is the initial concentration and is the decay rate or the inverse of the fluorescence lifetime.
Another factor is that the emission of fluorescence frequently leaves a fluorophore in the highest vibrational level of the ground state.
Divalent manganese, in concentrations of up to several percent, is responsible for the red or orange fluorescence of calcite, the green fluorescence of willemite, the yellow fluorescence of esperite, and the orange fluorescence of wollastonite and clinohedrite.

0.202 seconds.