Help


[permalink] [id link]
+
Page "Fluorescence" ¶ 29
from Wikipedia
Edit
Promote Demote Fragment Fix

Some Related Sentences

fluorescence and lifetime
Thus, if the rate of any pathway changes, both the excited state lifetime and the fluorescence quantum yield will be affected.
The fluorescence lifetime refers to the average time the molecule stays in its excited state before emitting a photon.
where is the concentration of excited state molecules at time, is the initial concentration and is the decay rate or the inverse of the fluorescence lifetime.
The decay times of this fluorescence are of the order of nanoseconds, since the duration of the light depends on the lifetime of the excited states of the fluorescent material, in this case anthracene or stilbene.
* FRET Fluorescence resonance energy transfer is used to study protein interactions, detect specific nucleic acid sequences and used as biosensors, while fluorescence lifetime ( FLIM ) can give an additional layer of information.
Furthermore, it was shown that the lifetime of fluorescence is determined by the size of the quantum dot.
This technique uses convolution integral to calculate a lifetime from a fluorescence decay.
The fluorophores in this region receive high intensity illumination which causes their fluorescence lifetime to quickly elapse ( limited to roughly 10 < sup > 5 </ sup > photons before extinction ).
The FRET efficiency relates to the quantum yield and the fluorescence lifetime of the donor molecule as follows:
Also, the fact that time measurements are over seconds rather than nanoseconds makes it easier than fluorescence lifetime measurements, and because photobleaching decay rates do not generally depend on donor concentration ( unless acceptor saturation is an issue ), the careful control of concentrations needed for intensity measurements is not needed.
FRET efficiency can also be determined from the change in the fluorescence lifetime of the donor.
This number varies over several orders of magnitude depending on the sample, and is known as the fluorescence lifetime of the sample.
In the above, is time, is the fluorescence lifetime, is the initial fluorescence at, and are the rates for each decay pathway, at least one of which must be the fluorescence decay rate.
Since the excited state has a lifetime, the fluorescence will be delayed with respect to the excitation signal, and the lifetime can be determined from the phase shift.
Also, y-components to the excitation and fluorescence sine waves will be modulated, and lifetime can be determined from the modulation ratio of these y-components.
Since the fluorescence lifetime of a fluorophore depends on both radiative ( i. e. fluorescence ) and non-radiative ( i. e. quenching, FRET ) processes, energy transfer from the donor molecule to the acceptor molecule will decrease the lifetime of the donor.

fluorescence and is
In fluorescence spectroscopy, the fluorescence anisotropy, calculated from the polarization properties of fluorescence from samples excited with plane-polarized light, is used, e. g., to determine the shape of a macromolecule.
The fluorescence signal is captured by a photomultiplier a known distance downstream of the de Laval nozzle.
This process is called fluorescence.
When the emission of the photon is immediate, this phenomenon is called fluorescence, a type of photoluminescence.
The most striking examples of fluorescence occur when the absorbed radiation is in the ultraviolet region of the spectrum, and thus invisible to the human eye, and the emitted light is in the visible region.
The chemical compound responsible for this fluorescence is matlaline, which is the oxidation product of one of the flavonoids found in this wood.
Molecular oxygen ( O < sub > 2 </ sub >) is an extremely efficient quencher of fluorescence just because of its unusual triplet ground state.
The maximum fluorescence quantum yield is 1. 0 ( 100 %); every photon absorbed results in a photon emitted.
Another way to define the quantum yield of fluorescence, is by the rate of excited state decay:
The quinine salt quinine sulfate in a sulfuric acid solution is a common fluorescence standard.
Another factor is that the emission of fluorescence frequently leaves a fluorophore in the highest vibrational level of the ground state.
Divalent manganese, in concentrations of up to several percent, is responsible for the red or orange fluorescence of calcite, the green fluorescence of willemite, the yellow fluorescence of esperite, and the orange fluorescence of wollastonite and clinohedrite.

fluorescence and important
This is especially important in low-light applications such as fluorescence microscopy.
Fused quartz slides are often used when ultraviolet transparency is important, e. g. in fluorescence microscopy.
to as parametric fluorescence or parametric scattering ) is an important process in quantum optics, used especially as a source of entangled photon pairs, and of single photons.
TIRF can also be used to observe the fluorescence of a single molecule, making it an important tool of biophysics and quantitative biology.
These microscopes have become an important part in the field of biology, opening the doors for more advanced microscope designs, such as the confocal microscope and the total internal reflection fluorescence microscope ( TIRF ).

fluorescence and parameter
Segal, Texas red, a hydrophilic, red-emitting fluorophore for use with fluorescein in dual parameter flow microfluorometric and fluorescence microscopic studies.

fluorescence and for
Advances in design of diode lasers and optical parametric oscillators promote developments in fluorescence and ionization spectrometry and also in absorption techniques where uses of optical cavities for increased effective absorption pathlength are expected to expand.
Chemical kinetics experiments can then be carried out in a " pump-probe " fashion using a laser to initiate the reaction ( for example by preparing one of the reagents by photolysis of a precursor ), followed by observation of that same species ( for example by laser-induced fluorescence ) after a known time delay.
With a few exceptions related to high-energy photons ( such as fluorescence, harmonic generation, photochemical reactions, the photovoltaic effect for ionizing radiations at far ultraviolet, X-ray, and gamma radiation ), absorbed electromagnetic radiation simply deposits its energy by heating the material.
An early observation of fluorescence was described in 1560 by Bernardino de Sahagún and in 1565 by Nicolás Monardes in the infusion known as lignum nephriticum ( Latin for " kidney wood ").
In 1819 Edward D. Clarke and in 1822 René Juste Haüy described fluorescence in fluorites, Sir David Brewster described the phenomenon for chlorophyll in 1833 and Sir John Herschel did the same for quinine in 1845.
Each of the following rules has exceptions but they are useful guidelines for understanding fluorescence.
Other advanced techniques, such as nonradioactive in situ hybridization, can be combined with immunochemistry to identify specific DNA or RNA molecules with fluorescent probes or tags that can be used for immunofluorescence and enzyme-linked fluorescence amplification ( especially alkaline phosphatase and tyramide signal amplification ).
Paper used for banknotes does not contain optical brighteners, so a common method for detecting counterfeit notes is to check for fluorescence.
For example, indirect immunofluorescence will allow for fluorescence colocalization and demonstration of location.
Between absorption, reflection, refraction and fluorescence, all of the incoming light must be accounted for, and no more.
Techniques for studying x-ray spectra include X-ray spectroscopy and X-ray fluorescence ( XRF ).
Monoclonal antibodies, specific to the virus, are also used for detection, as in fluorescence microscopy.
Conversely, AES is sensitive to the lighter elements, and unlike X-ray fluorescence, Auger peaks can be detected for elements as light as lithium ( Z = 3 ).

0.148 seconds.